XM-68 Mate 10D Laser Maxlipo Master Slim laser lipo System
Maxlipo Master Slim laser lipo System
Price: 2395usd
Laser
Female "three phases" (physiological period, pregnancy, lactation).
Customers with use hormones during treatment.
Customers with blood system disease.
Customers with the use of excessive exercises within 2 months in the treatment area.
Implanted cardiac pacemakers or other implanted electronic devices.
Life-sustaining artificial heart-lung machines and other equipment.
Portable ECG measurement equipment.
The following patients should be agreed by the professional doctors before using the equipment:
Customers with acute disease;
Malignancy;
Customers with Infectious diseases;
Customers with heart diseases;
Customers with fever;
Customers are receiving treatment or those with abnormal body phenomenon.
1. Theory
With the 532nm/635nm cold source laser, the 10 adjustable laser lamps target the fat cell beneath the treatment areas, creating a temporary pore within the fat cell, the fatty liquids can drain out of the cell,
the volume of the fat cell is reduced. The fatty acids and glycerol will be flushed out naturally though lymphatic metabolism.
2. Application
Eliminate excess fat in the abdomen, waist, back, buttocks, thighs, butterfly sleeves, double chin, and more, reduce the circumference of the treatment area to create an overall slimming effect.
There is no need to use anesthesia, there is no pain, numbness, will not cause scar, trauma, no need to recover. Due to specific wavelength, laser only acts on the subcutaneous fat cell layer,
other cells such as skin and capillary blood vessels will not be damaged during this process, safe and reliable way to reduce fat.
Cautions
(1) Cautions before Treatment
Before using this machine, be sure to check if the parts are connected correctly.
Insert the power supply first, turn on the total switch of the instrument to avoid current reflow phenomena.
The accessory cable must be aligned with the socket when accessing the host, avoiding the accessory jack interruption caused by the accessories.
Carefully move the machine, organic glass cannot wipe with alcohol.
When adjusting the intensity, it is necessary to have a flexible adjustment (suitable for the mainstay) according to the customer's ability, so as not to cause discomfort in the skin.
(2) Cautions after Treatment
Customer is advised to take a 30 minutes walk or exercise everyday.
Drink 2 litres of water a day.
Avoid too greasy/oily food and sweets. Make dinner a smaller meal.
Reduce intake of caffeine and alcohol.
It is recommended to take VC 1000mg / time, 2 times a day after treatment.
7. Contraindications
(1) Female "three phases" (physiological period, pregnancy, lactation).
(2) Customers with use hormones during treatment.
(3) Customers with blood system disease.
(4) Customers with the use of excessive exercises within 2 months in the treatment site.
(5) Implanted cardiac pacemakers or other implanted electronic devices.
(6) Life-sustaining artificial heart-lung machines and other equipment.
(7) Portable ECG measurement equipment;
(8) The following patients should be agreed by the professional doctors before using the equipment:
Patients with acute disease;
Malignancy;
Patients with Infectious diseases;
Patients with heart diseases;
Patients with fever;
Patients are receiving treatment or those with abnormal body phenomenon.
8. Maintenance
(1) Warranty: one year from the date of purchase for the main unit. We are responsible for the maintenance in our factory in GZ. After the warranty period has expired, we will charge a service fee or component fee.
(2) Prohibited to use in the following environments:
Hot and humid environment;
Dusty environment;
Environment with much smoke or stream.
(3) Be sure to wipe the probe to avoid oxidation and damage to the machine.
(4) If there comes a failure, shut down the power immediately, and send it to the distributors or contact manufacturer for maintenance, Do not repair by yourself without guidance.
(5) Exclusion of liability:
① if fire, earthquake or war occurred;
② The fault of user, operator error;
③ Damage caused by using other purpose (not included in the use manual);
④ Operate without manual’s guide;
⑤ Do not make the machine close to the wall, keeping a 30cm space around for cooling.
9. Parameters
Power | 800W |
Wavelength | 532nm/635nm/532nm+635nm(Optional) |
Treatment Area | About 30mm*800mm |
Mode | Continuous; Pulse |
Energy Output | 1-200mW(Continuous); 1-300mW(Pulse) |
Intensity | Level 1-3 (adjustable) |
Rotation Speed | Level 1-3 (adjustable) |
Screen | 12.1inch Touch Colour Screen |
Fuse | 5A |
Cooling System | Air cooled |
Package Size | 117cm*59cm*68cm |