Single Output Off Grid Online Solar Inverter 1kw For Solar System - LI-10212
Single Output Off Grid Online Solar Inverter 1kw For Solar System For Sale, Most Competitive Price, Fast Delivery, Custom Service, Wholesale Single Output Off Grid Online Solar Inverter 1kw For Solar System, Made in China, High Quality Products!, China cheap prodocuts, china suppliers Supplier, Manufacturer.Features:
Adjustable mains priority and inverter priority mode:
Mains priority: When AC mains and DC battery are connected at the same time, inverter chooses AC mains for priority AC output.
Inverter priority: When AC mains and DC battery are connected at the same time, inverter converts DC battery power for priority AC output.
Customers can choose mains priority or inverter priority mode according to their own needs, and can switch them at any time.
?
Brand new and imported U.S. brand Infineon IR MOSFETs are used for the whole series:
1000W-3000W:US IR brand MOSFETs
4000W-6000W:US IR brand COOL MOS 3077 MOSFETs, higher level MOSFETs
?
- - - -
Model | LI-351 | LI-501 | LI-601 | LI-102 | LI-152 | LI-202 | LI-302 | LI-502 | LI-702 | LI-103 | LI-153 | LI-203 |
Rated Power | 350W | 500W | 600W | 1KW | 1.5KW | 2KW | 3KW | 5KW | 7KW | 10KW | 15KW | 20KW |
Peak Power | 700W | 1000W | 1200W | 2KW | 3KW | 4KW | 6KW | 10KW | 14KW | 20KW | 30KW | 40KW |
Nominal battery voltage | 12VDC | 12VDC/24VDC | 24VDC/48VDC | 48VDC | 96VDC | 192VDC |
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) / 84-120VDC (96V) / 168-240VDC (192V) |
AC Mains input range | (220/230/240VAC) 140-275VAC | 170-250VAC |
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz (50Hz/60Hz automatic recognition) |
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) / ≤84VDC (96V) / ≤168VDC (192V) alarm |
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) / ≤80VDC (96V) / ≤160VDC (192V) automatic shutdown |
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) / ≥120VDC (96V) / ≥240VDC (192V) alarm |
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) / ≥136VDC (96V) / ≥272VDC (192V) automatic shutdown |
Over load protection | 110% more than rated capacity, automatic shutdown |
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown |
Short circuit protection | Automatic shutdown |
Output | Transfer efficiency | ≥85% |
Output voltage | (DC battery mode) 220/230/240VAC±2% |
Output frequency | (DC battery mode) 60/50Hz±1% |
Output wave form | Pure sine wave |
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) |
AVR output stablizer | AC mains<140VAC±5% swtich to DC battery mode, AC mains>150VAC ±5% return to AC mains mode; |
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; |
The above is for output 220V system reference, 230V/240V output just multiply by percentage |
Output frequency | (AC mains mode) automatic tracing from AC input |
Other | Transfer time | ≤10ms |
Display | LCD Display with function buttons |
Cooling system | Intelligent cooling fan control system |
≤42℃ slow fan, ≥45℃ fast fan |
AC Charger | AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V)/108.8-113.6VDC(96V)/217.6-227.2VDC(192V) |
AC charging current | Steady 15A |
AC over charge protection | Battery ≧16V (12V) ≧32V (24V) ≧64V (48V) ≧128V (96V) ≧256V (192V), stop charging after 60s alarm |
Working mode
(Optional) | 01 | AC mains priority |
Always use AC mains as priority input to provide AC output and automatically charge the battery, |
only stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off |
02 | Energy saving |
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on |
03 | DC battery priority |
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts DC to |
AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC output and |
automatically start charging the battery (for 24V/48V/96V/192V system, multiply by 2/4/8/16 accordingly) |
Comnunication | RS-232/USB/SNMP(additional option) |
Environment | Temperature | -20~75℃ |
Humidity | <95% |
Appearance | Product size (mm) | 300*240*120 | 410*225*410 | 485*300*655 |
Packing size (mm) | | | |
Net Weight (kg) | 7.2 | 7.5 | 7.5 | 8.7 | 23.5 | 25.5 | 28.8 | 55 | 56 | 85 | 105 | 125 |
Gross Weight (kg) | | | | | | | | | | | | |
*Product specifications are subject to change without further notice |
- - - -
About us:
More than 13 years – we are more than 13 years professional in manufacturing inverter, power inverter, solar inverter and so on. And we have more than 7 years’ experience in international trade service. We offer 24 hours service
Powerful production capacity - we can offer 3000 pcs a week.
We promise you the in time shipment.
Certification –Our inverter have CE and FCC certification, which mean we can offer you the high quality inverter.
?
?
Foshan Top One Power Technology Co., Ltd
Address: 5F, Bldg.2,,No.117 Zhangchayi Road, Guangzhou, Guangdong, China, 510000
Tel: +86-757-82589781
Foshan Top One Power Technology Co., Ltd 聽is specializing in manufacturing and marketing high quality new energy proudcts, the main products include inverter, power Inverter,solar power inverter, solar controller, pure sine wave inverter, frequency inverter,battery inverter, solar controller, a