RF Skin Rejuvenation Machine With EMS Function
BR807
RF Skin Rejuvenation Machine With EMS Function
Theory
RF
Radio frequency radio waves enter the deep part of the skin, and the internal natural resistance movement causes the skin to heat up. The use of dermal collagen cellulose immediately produce a contraction principle at 45 – 60℃, which can smooth wrinkles, tighten the skin and delay skin aging.
Fractional RF
Each pulse emits radio frequency energy through multiple matrix points, which is directly heated under the skin; under the stimulation of matrix needles, subcutaneous produce a large amount of collagen, and use radio frequency to directly heat under the skin to repair broken collagen fibers, so as to achieve a better repair effect.
EMS
Electrical Muscle Stimulation(EMS), also known as neuromuscular electrical stimulation(NMES) or electromyostimulation, is a protocal that elicits a muscle contraction using electrical impulses that directly stimulate your motor neurons. The stimulation creates muscle contractions that can be quick and frequent, fat with long pauses, or contractions that are held for several seconds or minutes at a time.
According to human neurology, 600 times electronic pulse currents per minute directly act on muscle nerve, can deeply reach the fat body, stimulate the most intensive neuro to induce muscle to generate shrinkage exercise. In the rapid active state of fat cells, the local fat layer is sufficient exercise, the body's basal metabolism is improved, and the effect is still continued within 24 hours after use. The kinetic energy is transformed into slimming energy, quickly eliminates human fat, and achieves more slimming effect than traditional methods, and tightens the curve of the whole body.
Parts Introduction
Parameters
Power | ≤150W |
RF | 1 MHz |
Screen | 8 inch color touch screen |
handles | EMS Bi-polar RF 1 piece; EMS Four polar RF 1 piece |
Fractional RF Handles 4 pieces | |
Voltage | 110V/220V, 50Hz/60Hz |
Package | 42cm*42cm*33cm |
Operation
Cautions
Before using this instrument, be sure to check whether the accessories are connected correctly.
First plug in the power line, then turn on the main switch of the equipment.
The accessory cable must be aligned with the socket when connecting to the host.
Avoid plugging in the accessory jack and causing the accessory to be unusable.
Move the instrument carefully.
After treatment, be sure to clean and disinfect the accessories.
Be sure to wipe the accessory probes clean to avoid incomplete disinfection, resulting in damage to the instrument and oxidation of the accessories.
When adjusting the energy, it is important to adjust it flexibly from low to high (appropriate) according to the customer's tolerance. It must not be too high and cause discomfort to the skin.
Do not swing the power cable into the power socket. It will cause poor contact.
The connecting wire of the treatment handle should be stretched with moderate force and not pulled hard.
Metal objects (necklaces, rings, etc.) should not be worn during treatment.