Protection Relay Testing / 50 Overcurrent Relay 3066i - K3066i
Protection Relay Testing / 50 Overcurrent Relay 3066i For Sale, Most Competitive Price, Fast Delivery, Custom Service, Wholesale Protection Relay Testing / 50 Overcurrent Relay 3066i, Made in China, High Quality Products!, China cheap prodocuts, china suppliers Supplier, Manufacturer.Protection Relay Testing / 50 Overcurrent Relay? 3066i
?
Relay protection test devices
1.Easy test
2.operation menu, Simple operation
3.Nominal input voltage:220VAC
4.Power:1000VA
?
?Friendly PC software for easy operation!
K30 series relay tester is extremely design for overseas user, with Friendly PC software as your need, unique features and functions helps you all the way!
?1.?Unique?self protection?system?assure?the?powerful?protection?when?instrument?is?operating, ?automatic?stop?the?output?when the?network?is?abnormal?;
2.?Unique?power?switch?and?amplifier?technology, ?so?the?output?precision?and?power?efficiency?and?factor
?are?increased, ?which?conforms?to?international?tendency?of?energy?save?and?environmental?protection;
3.?With?alarm?function?of?housing?grounding?testing?and?external?voltage?input, ?to?guaranty?personal?security;
4.?Two?in?one?of?meter?and?source, ?with?function?of?both?internal?and?external?testing, ?self-calibration, ?oscillograph, ?and?the?duration?of?each?oscillograph?reaches?50S?(optional?function);
5.?Offer?independent?Aux.?DC?to?tested?devices, ?0?~?300V/0.6A?(Poleless?and?adjustable);
6.?Function?of?transducer?and?energy?meter?testing?(optional?function);
7.?Testing?interface?offer?unique?output?monitoring?function?and?Pre-curve-tracing?function, ?helps?more?on?the?spot?analysis;
?
Technical?Data?of?K3066i
- - - -
Voltage?generators |
Setting? Range | 7-phase?AC?(L-N) | 7?x?0?...?300?V? |
2-phase?AC?(L-L) | 2?x?0?...?600?V |
Power | 7-phase?AC?(L-N) | 7?x?110VA, ?at?0?...?300?V |
2-phase?AC?(L-L) | 2?x?220VA, ?at?0?...?600?V |
Accuracy | <0.07%?reading?+?0.03%?range?guaranteed? at?0?...?300?V <0.02%?reading?+?0.01%?range?typical? at?0-300V |
Resolution | 1mV |
Current?generators |
Setting? Range | 6-phase?AC?(L-N) | 6?x?0?...?30?A |
3-phase?AC?(2L-N) | 3?x?0?...?60?A?(Group?A?II?B) |
1-phase?AC?(3L-N) | 1?x?0?...?180?A? |
Power | 6-phase?AC?(L-N) | 6x?450VA?, at?0?...?30A? |
3-phase?AC?(2L-N) | 3x?520VA, ?at?0?...?60A?(Group?A?II?B)? |
1-phase?AC?(3L-N) | 1?x?1000?VA, ?at?0?...?180A?(Max.) |
Accuracy | <0.07%?reading?+?0.06%?range?guaranteed?at?0-30A? <0.02%?reading?+?0.02%?range?typical?at?0-30A |
Resolution | 1mA |
Generators, ?general |
Frequency | Range | 0?...?1000?Hz |
Accuracy?/?drift | Error?0.001Hz?at?10?...?65Hz, Error?0.01Hz??at?65Hz...450Hz Error?0.02Hz??at?450Hz...1000Hz |
Resolution | 0.001Hz |
Phase | Range | -?360°?...?+360° |
Accuracy?/?drift | Error?0.2?° |
Resolution | 0.1° |
Timer | Range | Infinite |
Accuracy?/?drift | Error<0.1ms |
DC?generators |
Voltage?ranges | 0?...?300V/180W |
Current?ranges | 0?...?20A/300W |
Accuracy | <0.07%?reading?+?0.03%?range?guaranteed?at?0-300V? <0.04%?reading?+?0.02%?range?typical?at?0-300V |
<0.14%?reading?+?0.06%?range?guaranteed?at?0-20A <0.05%?reading?+?0.02%?range?typical?at?0-20A |
Resolution | 1mA;?1?mV |
Aux?DC?Supply |
Range | 0...300V/150W |
Binary?inputs |
Number | 8?pairs |
Compatible?Voltage | 10V?...?250V??DC |
Binary?outputs |
Number | 4?Pairs |
Capacity | 250V/3A????AC/DC |
Synchronization |
Synchronization?mode | GPS |
Harmonic |
Harmonic?overlap?times | 2?...?20?times |
Power?supply |
Nominal?input?voltage | 220VAC±20% |
Power | 1000VA |
Nominal?frequency | 47Hz….65Hz |
Environmental?conditions |
Operation?temperature | -5°C?...?55?°C |
Storage?temperature | -20°C?...?75?°C |
Humidity?range | 5%?...?90?%, ?non-condensing |
Weight | 20?KG |
Dimensions | 460(D)×140?(W)×360?(H)?mm |
PC?connection | RJ45, |
- - - -
?
K30?Series?Protection?Relay?Test?Set:
- - - -
Model | Channels | AC?Outputs |
K3063i?/?K3063Li | 10?output?channels | 6*30A/3*40A/4*300V |
K3030i?/?K3030Li | 7?output?channels | 3*30A/4*300V |
K3066 | 13?output?channels | 6*20A/3*40A/7*130V |
K3063 | 10?output?channels | 6*20A/3*40A/4*130V |
K3040 | 7?output?channels | 3*40A/4*130V |
K3030 | 7?output?channels | 3*30A/4*130V |
- - - -
Major?functions:
- - - -
Items | IEEE(R)?No. |
Synchronization?relay | ? |
Fault?transplay | ? |
GPS?Synchronization? | ? |
Overcurrent?relays | 50/76 |
Inverse?time?overcurrent?relays | 51 |
Undercurrent?relays | 37 |
Ground?fault?relays | 50 |
Directional?overcurrent?relays | 67 |
Directional?ground?fault?relays | 67N |
Overvoltage?relays | 59 |
Undervoltage?relays | 27 |
Directional?voltage?relays | 91 |
Directional?power?relays | 32 |
Power?factor?relays | 55 |
Differential?protection?(differential?circuits) | 87 |
Distance?protection?equipment?(phase?by?phase) | 21 |
Negative?sequence?overcurrent?relays | 46N |
Motor?overload?protection | 51/86 |
Automatic?reclosing?devices? | 79 |
Tripping?relays | 94 |
Voltage?regulating?relays | ? |
Overimpedance?relays, ?Z> | ? |
Underimpedance?relays, ?Z | ? |
Time-delay?relays | ? |
- - - -
?
Electric Automation Company
Address: 6F, Block 4CD, TianAn Cyber Park, Shenzhen, Guangdong, China, 518000
Tel: 86-755-83418941
Kingsine Electric Automation Co., Ltd. has been specializing in R&D, production and sales of Electric Testing & Measurement Instruments since 1999 foundation who is also honored as the High-tech enterprise certification and Software enterprise certificate recognized by China authority. With