Portable Fotona 4D Fractional Co2 Laser Co2 Fraccionado Co2 Machine Laser Fotona Fractional Laser Vaginal Rejuvenation Machine

Fotona 4D Fractional Co2 Laser

Price: 2895USD

Portable Fotona 4D Fractional Co2 Laser Co2 Fraccionado Co2 Machine Laser Fotona Fractional Laser Vaginal Rejuvenation Machine
Get Quote

1. Working Theory
The CO2 laser is a gaseous laser with a wavelength of 10.6 μm that is fully absorbed through human biological tissue (all skin available). The sealed-off fractional CO2 laser, whose output laser-light is delivered through an articulated arm, which has better direction and higher energy density.
The CO2 laser operates in the invisible infrared waveband, and an aiming beam is required to see where the treatment beam will impact tissue more recently from a visible red diode laser. When the laser beam go through the focus lens, the produced heat will gasify the target tissue.
With fractional laser resurfacing the laser beam is broken up or fractionated into many small micro beams which are separated so that when they strike the skin surface small areas of the skin between the beams are not hit by the laser and left intact. These small areas of untreated skin promote a much more rapid recovery and healing with less risk of complications. The small areas treated by the fractional micro beams, called micro treatment zones, cause sufficient laser injury to promote new collagen production and resultant facial skin rejuvenation.

1. Working Theory

The CO2 laser is a gaseous laser with a wavelength of 10.6 μm that is fully absorbed through human biological tissue (all skin available). The sealed-off fractional CO2 laser, whose output laser-light is delivered through an articulated arm, which has better direction and higher energy density.

The CO2 laser operates in the invisible infrared waveband, and an aiming beam is required to see where the treatment beam will impact tissue more recently from a visible red diode laser. When the laser beam go through the focus lens, the produced heat will gasify the target tissue.

With fractional laser resurfacing the laser beam is broken up or fractionated into many small micro beams which are separated so that when they strike the skin surface small areas of the skin between the beams are not hit by the laser and left intact. These small areas of untreated skin promote a much more rapid recovery and healing with less risk of complications. The small areas treated by the fractional micro beams, called micro treatment zones, cause sufficient laser injury to promote new collagen production and resultant facial skin rejuvenation.

2. Application

(1) Removal of acne, acne pits and acne marks.

(2) Removal of fine lines and dry lines around the eyes, including eyelids and crow's feet.

(3) Anti-aging: skin lifting and tightening, wrinkle reduction, enlarged pores, photo-aging skin improvement. 

(4) Treatment of pigmented lesions such as freckles and ostrum miracles. 

(5) Scars: treatment of depressed, old, raised, vascular/fibrotic scars. 

(6) Stretch marks.

6. Contraindications

(1) People with scarring.

(2) Patients with severe diabetes mellitus, hypertension.

(3) Those with suspected malignant lesions in the treatment area.

(4) Active vitiligo and psoriasis, systemic lupus erythematosus.

(5) During pregnancy or lactation.

(6) Persons with photosensitivity.

(7) Those who have undergone chemical peels, abrasions and other skin peels.

(8) Those who use retinoid medication.

(9) Poor cardiopulmonary function and organic lesions of vital organs.

 

 

7. Product Maintenance

(1) Warranty: one year from the date of purchase for the main unit and six months for the handle. After the warranty period has expired, we will charge a service fee or component fee. 

(2) Medical equipment or household appliances in close proximity to the unit may cause operational faults due to interference.

(3) Prohibited to use in the following environments:

High temperature and humid environments;

Environments with dust;

Environment with a lot of oil fumes or water vapour.

(4) If a fault occurs during use, the power should be switched off immediately and must be dismantled and repaired by a professional or sent to a dealer or manufacturer for repair, not by yourself.

(5) After treatment, disconnect the power supply and ensure that it is unplugged from the mains socket.

(6) No free warranty will be provided for the following faults caused by the use of personal reasons:

faults caused by unauthorised disassembly or modification of the product;

malfunctions caused by inadvertent dropping;

faults caused by lack of reasonable maintenance;

malfunctions caused by not following the correct instructions for use.

 

 

beir  has a professional R&D team that boasts rich experience and profound industry knowledge.The first-class R&D team ensures industry-leading efficiency in product development and provides professional services, including OEM/ODM, to support customization demands.
   Every year, the company invests 15% of its annual revenue in new product research and development and product optimization and upgrade.
    Our professional team can provide customers with fast, accurate, and thoughtful pre-sales consultations and after-sales services, ensuring a worry-free purchasing and usage experience for customers.


8. Parameters


Working Mode

single pulse, continuous pulse, repeated pulse, ultra pulse

Output Power

0-60W (adjustable)

Input Power

450VA

Laser Type

Sealed-off CO2 laser

Laser Wavelength

10.6μm

Divergence Angle

4mrad

Focused Spot Diameter

≤0.4mm

Focal Length of working head

F=75mm (optional)

Pulse Width

0.02-0.99s

Indication Beam

Red Diode Laser (650nm,5mW)

Cooling System 

Air Cooling

Transmission System

7-Articulation Joint Spring Arm

Display Screen

LCD

Environmental Temperature

5-40

Relative Humidity

80%

Input power

AC220V±10%, 50Hz

Package Size

76cm×55cm×35cm

G. W.

40kgs


 