Needle burner tester
The device use needle flame to simulate small flame effect resulted from equipment incorrect operation so as to evaluate fire hazard.
Expose the specimen to fire in a certain time. The temperature of the copper block is measured by K-type mineral insulated metal sheathed thermocouples (level 1) conforming to IEC 60584-2
The calibration device is capable of automatically measuring the time interval between 100 ° C and 700 ° C and calculating the mean value of the three measurements. The calibration device is also equipped with a digital-analog temperature output that can be used to measure the external time interval.
Needle flame tester used not only for low-voltage electrical appliances, power tools, machine tools, electrical instruments, household appliances, electrical, electronic equipment, lighting, electrical connections, accessories and other electrical and electronic equipment and components, components research, production and quality Departments, but also for insulating materials, engineering plastics or other solid combustible materials industry