Industrial High Amp Hour Deep Cycle Batteries Rechargeable 12V3 5AH - CBL12350

Industrial High Amp Hour Deep Cycle Batteries Rechargeable 12V3 5AH For Sale, Most Competitive Price, Fast Delivery, Custom Service, Wholesale Industrial High Amp Hour Deep Cycle Batteries Rechargeable 12V3 5AH, Made in China, High Quality Products!, China cheap prodocuts, china suppliers Supplier, Manufacturer.
Industrial High Amp Hour Deep Cycle Batteries Rechargeable 12V3 5AH

Industrial High Amp Hour Deep Cycle Batteries Rechargeable 12V3 5AH

?

?

Specifications:

- - - -
Nominal Voltage | 12V | Capacity | C10 | 35Ah (10.5V, at 25℃) |
Nominal Capacity (C10) | 35Ah (10.5V,at 25℃) | C5 | 28Ah (10.5V, at 25℃) |
Dimension | Length 198mm | C3 | 26.25Ah (10.5V, at 25℃) |
Width 132mm | C1 | 19.25Ah (10.2V, at 25℃) |
Height 170mm | Internal Resistance | Approx. 12 mΩ (25℃) |
Total Height 170mm | Max Short-duration Discharge Current | 700A(25℃) |
Weight | Approx. 11.92kg | Terminal | FP-39/RT-36 |
? | ? | ? | ? | ? | ? |
- - - -

?

FEATURES

●?Designed life for floating charge is 5 years (20℃);

● Design with flat plate, GEL electrolyte and AGM separator technology;

● GEL electrolyte inside of battery keeps uniformity condition, battery is with excellent cycle life;

● GEL electrolyte has huge thermal capacity, thermal runaway phenomena never occur;

? ? ?● High strength ABS material for container & lid;

● Wide temperature scope of application(-15~45℃).

● Best temperature of application(20±5℃);

? ? ? ? ?● No leaking, safe and reliable;

● Standing or lying down for using, convenient to transport and install;

● Low self-discharge rate.

?

CHARGE

- - - -
Using Mode | Charging Voltage | Temperature Compensation | Max Charging Current |
Standby Use | 2.275±0.025V/cell (25℃) | -3.3mV/℃/cell | 57.5A |
Cyclic Use | 2.45±0.05V/cell (25℃) | -5mV/℃/cell |
- - - -

?

STORAGE

● Batteries should be stored in dry and clean warehouse which has good air exchange system. Batteries should avoid direct sunlight. Batteries should not be near to heat (such as radiator, the distance should more than 1m). Batteries should avoid any toxic gas and organic solvent.

● When the ambient temperature is less than 25℃, the longest storage life is 6 months. If ambient temperature is higher, the longest storage life varies as specified in below chart.

- - - -
Storage Temperature (℃) | ≤25 | 26~33 | 34~40 |
Storage Time (Month) | 6 | 3 | 1 |
- - - -

?

?

?

?

●Batteries should be recharged within the storage life or before using.

Charging methods: maximum charging current 57.5A, constant voltage 2.45±0.05V/cell (25℃);

Charging time: 15~20h; Temperature compensation coefficient: -5mV/℃/cell.

?

Applications:

? ? ? 1. UPS
? ? ? 2. Emergency lighting systems
? ? ? 3. Alarm and security system
? ? ? 4. Fire alarm and security system
? ? ? 5.Telecommunication system
? ? ? 6. Backup power for testing and measuring instruments
? ? ? 7. Communication power supply
? ? ? 8. Auto control system
? ? ? 9. Electronic apparatus and equipment
? ? ?10.DC power supply

?

Advantages

? ? ? 1.The battery is full of power when it’s out of factory, no need to use liquid charge;

? ? ? 2.no memory, no need to discharge battery use, suitable for circuit design;

? ? ? 3.by high partition, adsorption and strong;

? ? ? 4.there is no flowing liquid (poor liquid), does not leak acid and free Upside down,

? ? ? 5.comply with environmental requirements, ease of use,

? ? ? 6.the use of lead-calcium alloys, battery self-discharge is very low,

? ? ? 7.easy storage, less maintenance;

? ? ? 8.using ABS plastic shell and valve technology for safe use.

?

?

Notice:

1. Don’t near the hot source and don’t under the sunshine.

2. Don’t charge in the sealed container.

3. No short circuit. It should be addition charge if you don’t use, and single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.

4. Don’t store in the space of acid gas.

5. You should be careful and regular check when use the battery. To avoid the battery don’t work. You should change the battery if the capacity is not full or has been damage, especially after one year using.

6. Don’t put the battery in the fire, or it will explode.

7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.

8. Don’t clean the battery by using the organic solution. (e.g. petrol)

?

Get Quote

Wuhan Changguang Battery Co., Ltd

Address: Wuhan Economic Technology Development Zone, Wuhan, Hubei, China, 430000
Tel: 86-27-84891323
Wuhan Changguang Battery Co., Ltd (CGB), located in Wuhan Economic & Technology Development Zone, is established in 1993. It is a joint-venture company with the registered capital of 6.8 million US dollars which controlled by Wuhan Zhongyuan Electronics Group Co., Ltd.鈥斺?攁 wholly owned subsidiary company of China Electronics Corporation (CEC). CGB specializes in the manufacturing, research and development of rechargeable valve regulated lead acid (VRLA) battery. Our standard products range cover 2V, 4V, 6V, 8V, 12V with capacity 0.5AH to 3000AH. We are partnering with international reputable manufactures of UPS, alarm & security systems, solar energy systems, electronic instruments and medical equipment in developments and R&D projects of new products. We do believe in the near future, we will have a significant progress in new products.

Related Products

Send A Message
*If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.