Flow accuracy + 1%, High Performance Liquid Chromatography LC200, Column Oven with / without Chiller - LC200
Flow accuracy + 1%, High Performance Liquid Chromatography LC200, Column Oven with / without Chiller For Sale, Most Competitive Price, Fast Delivery, Custom Service, Wholesale Flow accuracy + 1%, High Performance Liquid Chromatography LC200, Column Oven with / without Chiller, Made in China, High Quality Products!, China cheap prodocuts, china suppliers Supplier, Manufacturer.?
?
Flow accuracy + 1%, Liquid Chromatography LC200, Column Oven with/without Chiller
?
?
?
Applications:
?
# Medical and pharmaceuticals
# Health and epidemic prevention
# Environmental monitoring
# Agriculture, forestry, fisheries, animal husbandry
# Manufacturing
# Petrochemical
# Quality control
# Education and scientific research
# Water reservation system
?
Features
# Accurate flow rate
# Excellent reliability and stability
# Full control via powerful LC Win software
# Modular design enables flexible configurations
# Automatic data save in the event of accidental power shortage
?
?
?
Specifications:
- - - -
LC210?Pump |
Type? | Serial?dual?plunger |
Flow?range | 0.001-10.000ml/min,?0.001ml/min?increment |
Compressive?compensation? | User?defined? |
Seal?wash | Manual |
Max?pressure | 40Mpa/5800psi |
Pressure?ripple | ≤1%?(1ml/min,?degassed?methol) |
Flow?precision | ≤0.075%RSD |
Flow?accuracy | +1% |
Number?of?solvents?and?setting?range | Isocratic,?0-100%,?0.1?increments |
Composition?accuracy | ≤2% |
Power?requirements | 95-240V?150VA?50Hz |
Dimension? | 392x550x169mm |
Weight? | 14.5kg |
Sound?pressure?level | <70dB |
? |
LC220?UV?Detector? |
Lamp?source | Deuterium?lamp,?Tungsten?lamp |
Wavelength?range | 190-800nm |
Bandwidth? | 6nm |
Wavelength?accuracy | +1nm |
Wavelength?precision | ≤0.2nm |
Linear?range | >104 |
Noise? | +0.75x10-5AU?(dry?cell,?254nm,?response?time?1s) |
Drift? | 1x10-4AU/h?(dry?cell,?24nm,?responses?time?1s) |
Detection?limit | ≤5x10-9g/ml?(naphthalene/methanol) |
Flow?cell?volume | 10μl |
Pressure?limit | 10Mpa/1500psi |
Responses?time? | 0.1-2s |
Operating?temperature?range? | 10-40℃ |
Power?requirements | 95-240V?150VA?50Hz |
Dimension? | 392x550x169mm |
Weight? | 12kg |
Sound?pressure?level | <70dB |
? |
LC230?Auto?Sampler |
Loop?volume?(100μl) | 1-5000μl?programmable?(10ml?loop?optional) |
Syringe?volume? | 500μl?(2500μl?optional) |
Sample?capacity | 2x48?vial?tray?for?1.5ml?vial?(optional?12?position?10ml?vial?tray,?96?well?plate?formats,?384?well?plate?formats) |
Switching?time?of?injection?valve | <100ms |
Piercing?precision?needle | ≤0.6mm |
Injection?cycle?time | 17s?(60s?while?needle?washing) |
Injection?modes | Full?loop,?partial?loopfill?and?μl?pickup?mode |
Reproducibility? | Full?loop?0.3% Partial?loopfill?0.5% Μl?pickup?1% |
Carry?over | <0.05% |
Cooling?(optional) | 4℃?to?ambient-3℃ |
Power?requirements | 95-240V?150VA?50Hz |
Dimension? | 300x510x360mm,?300x575x360?with?cooling |
Weight? | 19kg;?21kg?with?cooling |
Sound?pressure?level | <70dB |
? |
LC240?Column?Oven |
Model? | LC240 and LC242 LC241 and LC243 |
Temperature?range | Ambient?-?100℃,?0.1?increment? |
Temperature?accuracy? | +5℃ |
Temperature?stability | ≤0.1℃ |
Cooling?(optional) | Minimum?to?ambient?-?15℃ |
Columns?accommodated? | 3?columns,?15-25cm |
? |
LC250?Degasser |
Type? | LC250?membrane?online?degasser?2?channel LC251?membrane?online?degasser?3?channel LC252?membrane?online?degasser?4?channel |
Volume? | 10ml/min |
- - - -
?
- - - -
Diode?Array?Detector?2600 |
Light?source? | Deuterium |
Measurement?range | 190-500nm |
Detection?type? | Diode?array,?1.25nm?dot?pitch,?256?diodes |
Bandwidth? | 4-25nm,?user?selectable |
Wavelength?accuracy | ≤1nm |
Wavelength?validation | Automatic?via?internal?Holmium?Oxide?filter |
Noise? | ≤1x10-5AU |
Drift? | ≤5x10-5AU/hr |
Linearity? | 0-1.5AU |
Measurement?range? | 0-2.2AU |
Spectra? | 4?spectra?can?be?stored |
Integration?time?range | 13-200ms |
Time?constants? | 0.1-10.0?second?in?1-2-5?steps |
? |
ELSD?Detector?Chromachem |
Light?source? | High?intensity?Halogen?lamp?(multicolor) |
Detector? | Photomultiplier?(high?sensitivity) |
Analogue?signal?output | 0-1V |
Detect?limit | <10ng?glucose?(non-column?injection) |
Heating?time | <10min?heat?up?to?150℃ |
Temperature?range | Evaporation?chamber:?maximum?150℃,?increase?by?1℃ Nebulizer:?maximum?70℃ |
Autozero | Front?panel?or?external?trigger |
Nebulizer?type? | Venture?tube,?temperature?controllable |
Gas?flow?rate | 1-2l/min,?recommended?pressure?1-2bars |
Spectra | 4?spectra?can?be?stored |
Integration?time?range | 13-200ms |
Time?constants? | 0.1-10.0?second?in?1-2-5?steps |
? |
Refractive?Index?Detector?201H |
Refractive?index?range | 1.00-1.75 |
Detection?range | 0.25-512μRIU |
Linear?range | ≥600μRIU |
Noise? | ≤2.5nRIU?(pure?water,?response?time:?1.5second) |
Response?time | 0.1,?0.25,?0.5,?1,?1.5,?2,?3,?6?second |
Autozero | Automatic?zero |
Autozero?range | Full?range |
Deviation?adjustable?range | 10μRIU |
Detection?cell?volume | 8μl |
Flow?rate | Common?value?0.2-3.0ml/min,?maximum?10ml/min?(pure?water) |
Highest?pressure | 0.05Mpa |
Dead?volume | 670μl |
Temperature?control | Off,?30-50℃?(each?time?1℃),?77℃?fuse?(dual?temperature?control) |
? |
Fluorescence?Detector?RF20Axs? |
Light?source | Xenon?lamp?Low?pressure?Mercury?(for?wavelength?accuracy?correction) |
Wavelength?range | 200-750nm |
Spectral?bandwidth? | 20nm |
Wavelength?accuracy | +2nm |
S/N | Raman?peak?of?water?S/N?above?2000 |
Detection?cell?temperature?range | 4℃-40℃,?1℃?increment |
Detection?cell?temperature?control?range | (ambient-10)℃-40℃ |
Detection?cell? | Standard?detection?cell:?volume:?12μl,? withstanding?pressure:?2Mpa Half-micro?detection?cell:?volume:?12μl,? withstanding?pressure:?2Mpa |
Functions? | Simultaneous?double-wavelength?test,?wavelength?scanning |
Safety?protection? | Leakage?sensor |
Operation?temperature?range? | 4℃-35℃ |
- - - -
?
?
?
PG Instruments Limited
Address: China Office: No.3 Pingsan Road, Pinggu District, Beijing, China 101200; UK Office: Alma Park, Wibtoft, Leicestershire, LE17 5BH, United Kingdom, Beijing, Beijing, China, 100000
Tel: 86-010-69910653
PG Instruments Limited is a global manufacturer that has for many years engaged in developing and manufacturing UV-Visible Spectrophotometer and Atomic Absorption Spectrometer. Over the last few years, PG instruments has diversified and considerably added to our portfolio of instrumentation. Currently the product includes not only instruments, but also reagents and solutions. With thousands of instruments manufactured and shipped annually, PG is a dominant market participant and a price/performance leader in the analytical instrument market.