Durable 1000W Solar PV Inverter With 50A MPPT Charging Controller 12v Dc To 110v 220v For Sale, Most Competitive Price, Fast Delivery, Custom Service, Wholesale Durable 1000W Solar PV Inverter With 50A MPPT Charging Controller 12v Dc To 110v 220v, Made in China, High Quality Products!, China cheap prodocuts, china suppliers Supplier, Manufacturer.Durable 1000W inverter with 50A MPPT charging controller 12v dc to 110v 220v ac off grid solar inverter for solar system
?
FSI-10212M50
?
?
Features:
High Transfer efficiency:≥90%
Continuous stable pure sine wave output
with built-in AVR stablizer
Built-in MPPT solar charge controller
?
True Over Temperature Protection
Built-in realtime temperature monitoring probe can truly detect the inside temperature of inverter and transmit the data to the DSP intelligent chip in order to analyse the results of temperature, and to adjust the speed of fan and shut down function for protection.
?
?
?
?
?
- - - -
Model | FSI-102 | FSI-152 | FSI-202 | FSI-302 | FSI-402 | FSI-502 | FSI-602 |
Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW |
Peak Power | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW |
Nominal battery voltage | 12/24VDC | 12/24/48VDC | 24VDC/48VDC |
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) |
AC Mains input range | 170-275VAC (220/230/240VAC)±4% |
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition) |
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm |
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown |
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm |
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown |
Over load protection | 110%
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown |
Short circuit protection | Automatic shutdown |
Output | Transfer efficiency | ≥90% |
Output voltage | (DC battery mode) 220/230/240VAC±2% |
Output frequency | (DC battery mode) 60/50Hz±1% |
Output wave form | Pure sine wave |
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) |
AVR output stablizer | AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode; |
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; |
The above is for output 220V system reference, 230V/240V output just multiply by percentage |
Output frequency | (AC mains mode) automatic tracing from AC input |
Other | Transfer time | ≤5ms |
Display | LCD Display with function buttons |
Cooling system | Intelligent cooling fan control system |
≤42℃ slow fan, ≥45℃ fast fan |
AC Charger | 7 battery types mode | Gel U.S.A. / Gel European / A.G.M.1 / A.G.M.2 / Sealed lead acid / Open lead acid / Calcium(open) / |
Deep sulphation cycle 15.5 for 4 hrs |
AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) |
AC charging current | 0-35A: 5A / 10A / 20A / 25A / 30A / 35A, 6 stages adjustable option |
3 Stages charging | Boost charging, direct charging, float charging |
AC over charge protection | Battery voltage ≧16VDC (12V) ≧32VDC (24V) ≧64VDC (48V), stop charging after 60s alarm |
Working mode
(Optional) | 01 | AC mains priority |
Always use AC mains as priority input to provide AC output and automatically charge the battery, only |
stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off |
02 | Energy saving |
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on |
03 | DC battery priority |
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts |
DC to AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC |
output and automatically start charging the battery (for 24V/48V system, multiply by 2/4 accordingly) |
Comnunication | RS-232/USB/SNMP(additional option) |
Environment | Temperature | -20~75℃ |
Humidity | <95% |
MPPT Solar Controller specification | Charging & discharging | 30A / 50A | 50A |
Max. PV input voltage | Max. 30V(12V) / 50V (24V) / 100V (48V) |
Max. PV array Power | 360W (12V) / 720W (24V) | 1200W (24V) / 2400W (48V) |
MPPT range | 12-60VDC @ 12V & 24V system | 24-120VDC @ 24V & 48V system |
Max. PV array open circuit | 70VDC | 150VDC |
System voltage | 12V & 24V / 24V & 48V automatic recognition |
No load current | <5mA |
Charging circuit drop | ≤0.2V |
Discharging circuit drop | ≤0.15V |
Over charge protection | 17V (12V) / 34V (24V) / 68V (48V) stop charging |
Boost charging | 14.6V (12V) / 29.2V (24V) / 58.4V (48V) Duration: 30mins |
Direct charging | 14.4V (12V) / 28.8V (24V) / 57.6V (48V) Duration: 30mins |
Float charging | 13.6V(12V) / 27.2V (24V) / 54.4V (48V) until reach charging recovery voltage |
Charging recovery | 13.8V (12V) / 27.6V (24V) / 55.2V (48V) |
Over discharging recovery | 12.5V (12V) / 25V (24V) / 50V (48V) |
Low voltage | 10.5V (12V) / 21V (24V) / 42V (48V) alarm |
Over discharging | 10V (12V) / 20V (24V) / 40V (48V) automatic shutdown |
Temperature compensation | {-4.0mv/℃/2V(Boost charging, Direct charging, float charging and charging recover voltage compensation) |
Control method | MPPT smart charging, maximum power point tracking |
Working temperature | -20~75℃ |
Circuit protection | Over charging, over discharging, overload and short circuit protection | All protections are harmless to any parts and fuse of controller; fuse is only for ultimate protection. |
Anti connection-reverse protection for solar panel |
Appearance | Product size (mm) | 420*285*200mm | 620*282*210mm |
Packing size (mm) | 530*335*255mm | 740*355*275 |
Net Weight (kg) | 16.5kg | 19kg | 27kg | 31kg | 41.5kg | 47.5kg | 53kg |
Gross Weight (kg) | 19.5kg | 22kg | 31kg | 35kg | 46kg | 52kg | 57.5kg |
*Product specifications are subject to change without further notice |
- - - -
?
Why you choose us:
?
1.Professional--Over 10 years Professional Solar inverter & UPS Power System Producing Experience.
2.Powerful productivity-- We can produce high frequency inverter 30000 pcs/ month, low frequency inverter 3500 pcs/month.
3.Hi-tech-- Powerful R&D department can provide professional technical support.
4.Certification-- Applied with CE, FCC certification.
5.Warranty--One year warranty.
Our service
?
OEM service: We offer Professional OEM service. We have a comprehensive
R&D team:
proficient in exterior design, packaging design, programming, wiring, structuraloptimization,etc. We are confident to satisfy you on both hardware and software.
After-sales team: We have a specialized after-sales team to help answer question for 24 hours. When problem arises while using or need to adapt to the local grid, our after-sale engineer will follow up the issue.
?
Foshan Top One Power Technology Co., Ltd
Address: 5F, Bldg.2,,No.117 Zhangchayi Road, Guangzhou, Guangdong, China, 510000
Tel: +86-757-82589781
Foshan Top One Power Technology Co., Ltd 聽is specializing in manufacturing and marketing high quality new energy proudcts, the main products include inverter, power Inverter,solar power inverter, solar controller, pure sine wave inverter, frequency inverter,battery inverter, solar controller, a