Duplex Cores Aerial Bundled ABC Cable ACSR Conductor For Overhead Power System - ABC-ACSR/XLPE 0.6/1KV
Duplex Cores Aerial Bundled ABC Cable ACSR Conductor For Overhead Power System For Sale, Most Competitive Price, Fast Delivery, Custom Service, Wholesale Duplex Cores Aerial Bundled ABC Cable ACSR Conductor For Overhead Power System, Made in China, High Quality Products!, China cheap prodocuts, china suppliers Supplier, Manufacturer.Duplex Cores Aerial Bundled ABC Cable ACSR Conductor For Overhead Power System
?
Description
?
The aerial Bundled cables designed for overhead distribution lines have an insulated neutral messenger made of AAAC, which the insulated aluminium phase conductor are helically wound over it. Cables are rated at 0.6/1(1.2)kV and conform to IEC60502.
?
Construction
?
# # Conductor:
?
a) Phase - The phase conductor shall be of H68 Condition aluminium conductor and compacted circular stranded.
?
b) Neutral or messenger - The Neutral or messenger conductor shall be of aluminium alloy conductor and compacted circular stranded.
?
# # Insulation:
?
The phase, neutral conductors shall be extruded with polyethylene(PE) as insulation.
?
?
?
?
?
?
1 Phase conductor + 1 Messenger conductor
?
?
?
?
?
?
?
Schedule of technical particulars
?
- - - -
Phase conductor | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? |
Nominal cross-sectional area | mm2 | 16 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
Number of cores | ? | 1 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
Minimum number of wires | ? | 6 | 6 | 6 | 6 | 6 | 12 | 15 | 15 | 30 | 30 |
Nominal insulation thickness | mm | 1 | 1 | 1.2 | 1.2 | 1.4 | 1.4 | 1.6 | 1.6 | 1.8 | 2.0 |
Diameter of insulated core | mm | 6.8 | 6.8 | 8.5 | 9.5 | 11.2 | 13.0 | 15.1 | 16.6 | 18.4 | 20.6 |
Max. DC resistance at 20℃ | ohm/km | 1.91 | 1.91 | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | 0.164 |
Current rating at still wind, ambient | A | 61 | 61 | 84 | 104 | 129 | 167 | 209 | 246 | 283 | 332 |
temperature=30℃ |
Conductor temperature=75℃ | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? |
Messenger conductor | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? |
Nominal cross-sectional area | mm2 | 25 | 25 | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | ? | 6 | 6 | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20℃ | ohm/km | 1.312 | 1.312 | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Calculated breaking load | kN | 6.4 | 6.4 | 6.4 | 6.4 | 8.9 | 12.1 | 18.0 | 18.0 | 24.2 | 30.8 |
Completed cable | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? |
Approx. overall diameter | mm | 15.3 | 19.0 | 23.2 | 25.6 | 30.0 | 34.9 | 40.6 | 44.1 | 49.2 | 54.9 |
Approx. weight of cable | kg/km | 160 | 290 | 400 | 500 | 680 | 920 | 1270 | 1510 | 1870 | 2340 |
- - - -
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
?
GB12527-91,IEC502, BS7870-5
Other Tech Standards such as BS,DIN and ICEA upon request.
?
?
?
?
?
?
?
?
?
?
?
Shanghai Shenghua Cable (Group) Co., Ltd.
Address: No.7577 Hunan Road, Pudong New District. Shanghai China, Shanghai, Shanghai, China, 200000
Tel: 86-21-68172999
Shanghai Shenghua Cable (Group) Co., Ltd, established in 1997, is an integrated enterprises with R&D, production and trading together. After 19 year development, Shenghua has founded 6 cable manufacturing bases in China including Shanghai, Anhui, Henan, Liaoning, Haerbin, and Ningxia Province. The t