ACLS Intelligent Child First Aid Manikins for Hospitals , Colleges Training - AIA-1
ACLS Intelligent Child First Aid Manikins for Hospitals , Colleges Training For Sale, Most Competitive Price, Fast Delivery, Custom Service, Wholesale ACLS Intelligent Child First Aid Manikins for Hospitals , Colleges Training, Made in China, High Quality Products!, China cheap prodocuts, china suppliers Supplier, Manufacturer.?
ACLS Intelligent Child First Aid Manikins for Hospitals , Colleges Training
?
?
Specifications:
- - - -
1. Material: | Imported PVC |
2. Age: | Five-year-old,?One-year-old |
3. Logo: | General?Doctor? |
4. Product?Name: | Child First Aid Training Manikin |
5. Warranty?Period: | 1?Year |
6. Usage: | Colleges Researching ?for Child CPR Simulation |
7. Type: | Child Manikin |
8. OEM?Accepted: | Yes |
9.?Certificate?Available: | ISO?9001-2000? |
- - - -
?
?
Description:?
GD/ACLS1600 is designed according to experts experience and advice in the first-aid field and in accordance with five-year-old child anatomical characteristic. Complying with AHA (American Heart Association) 2005 emergency guideline for CPR and ECC, GD/ACLS1600 provides abundant real first-aid scenes for emergency physicians to train first aid operation process via friendly man-machine interface. The product is made of imported material with soft, elastic and not easily deformed skin, which is a good helper for pediatric teaching. It is the world leading man-machine interaction child ACLS training simulation system, can simulate real emergency scenes and all the related signs of emergency patient, such as: pupil states, artery pulse, heart rhythm, heart and lung auscultation sound, etc.
?
?
Features:
?
Head and Neck:
1. Pupil observation, one side is normal, the other side is dilated; the Flash animation displays light reaction and diameter changes of pupils;
2. Simulate airway foreign obstruction: foreign body obstruction in pharynx, main airway obstruction;
3. Carotid artery is available for five-year old child;
4. Respiration mode:Normalbreath, oligopnea, tachypnea, superficial respiration, excessive respiration, Kussmaul’s respiration, Cheyne-stokes respiration, meningitic breathing, sighing breath, irregular gasping, breathing holding;????
5. Voice: including crying, laughing, moaning, coughing, gasping and all kinds of complaints, etc;
6. Airway management: realistic mouth, nose, tongue, gum, throat, esophagus, epiglottis, trachea (the diameter of the simulative airway:?9mm); can practice tracheal intubation via mouth, sputum suction; simulate airway foreign body obstruction conditions(pharyngeal and main airway obstruction); can practice tracheal incision; only right lung ventilation due to excessive intubation position.
?
Chest and Abdomen:
1. Manikin organs include: bilateral lungs, stomach, bladder, rectum, bilateral lungs ventilation, liquid can be infused and drained out from bladder and rectum;?
2. Simulate spontaneous breathing, chest rise; can perform bilateral, left side , right side chest rise;
3. Bilateral puncture decompression and puncture effusion can be performed;
4. Femoral artery pulse
5. Auscultatory sound: including heart sound, respiratory sound, bowel sound; and the normal heart sound and respiratory sound can be adjusted according to the heart rate and respiratory frequency;
6. Gastric intubation: can perform gastric lavage, gastrointestinal decompression operation; intubation position can be detected via abdominal auscultation; suction of gastric liquid indicates successful intubation;?
7. Vital signs monitor: ECG, heart rate, respiratory frequency, BP, body temperature, saturation of blood oxygen, end-tidal partial pressure of CO2, etc; the flash can simulate spasm condition;?
8. Simulate skin color: normal, central cyanosis, peripheral cyanosis, mixed cyanosis, pale;
9. Urethral catheterization: can change male/female perineum to practice male/female catheterization;
10. CPR: Support multiple ventilation ways: mouth to mouth, mouth to nose, BVM to mouth; electronic monitoring of airway open, inflation times, frequency, volume and compression times, frequency, position and depth; automatic judgment of artificial respiration and chest compression ratio; English voice prompts during the entire process;
11.?AED, defibrillation and pacing: multimedia animation displays AED and defibrillation process;
1.Real defibrillation and pacing: Achieve real defibrillation and pacing by using with real defibrillating pacer(prepared by user-self);
2. ECG monitoring: Be used with real ECG monitor (prepared by user-self) to realize ECG monitoring,Simulative ECG monitoring should be used with GD/J115 multi-parameter simulation of ECG to achieve the function of monitoring ECG.
3. Simulate defibrillation and pacing: should be used with GD/J880; can choose defibrillation energy, the max energy is 360J;
4. Simulate AED: be used with GD/AED99Fto simulate AED operation; English voice prompts during the entire process; providing electrode button; automatic heart rhythm detection and analyze if the defibrillation is needed.
?
Limbs:
1. Manual BP measuring arm can simulate BP measurement with Korotkff sound;
2. Venous puncture/transfusion: arm vein, femoral vein, dorsal vein of foot
3. Skin care
4. Intramuscular injection: bilateral deltoid , bilateral vastus lateralis;
5. Bone marrow puncture: tibia with obvious body surface symbol, effusion of simulative bone marrow indicates proper puncture operation;
?
Software:
1. Provide various kinds of drug and multiple administration ways: i.v. drops, i.v., hypo., intramuscular injection, anal plug, injection pump, transfusion pump, etc; general dose and usage of each drug is preset; some drugs exist pharmacodynamic physiological reaction;?
2. Provide all kinds of auxiliary examination: biochemical report, CT, ultrasound, ECG, etc;
3. Training and examination, ECG identification training, CPR training and examination are available in the system;
4. Simulative cases training and assessment: Provide various clinical cases script
5. Perform PETCO2:? confirm tracheal intubation position and monitor the effectiveness of resuscitation operatio
?
?
Standard Component:
?
GD/ACLS1600A?Standard Components:
1. Intelligent ACLS Five-year-old Child Manikin
2. GD/HS7 BP Training Equipment
3. Heart and Lung Auscultation Simulator Set
4. GD/XD1000CECG Generator
5. GD/CC999CDefibrillator Converter
6. BVM, Stethoscope, Laryngoscope, Tracheotomy tube, Infusion set.
7. Emergency System Controller
8. Medical Air Compressor
?
GD/ACLS1600B Standard Components:
1. Intelligent ACLS One-year-old Child Manikin
2. GD/HS7 BP Training Equipment??????
3. Heart and Lung Auscultation Simulator Set
4. GD/XD1000CECG Generator
5. GD/CC999CDefibrillator Converter
6. BVM, Stethoscope, Laryngoscope, Tracheotomy tube, Infusion set.
7. Emergency System Controller
8. Medical Air Compressor
?
?
Pictures Show:
Shanghai Honglian Medical Tech Group
Address: 5th Floor, No.1 Bldg, Aijia International Bldg, Shanghai, Shanghai, China, 200000
Tel: 86-021-55964925
Shanghai Honglian medical聽Tech Group was established in 1993. Now Honglian has developed to be a high-tech enterprise with its own research and development, production, sales and service system. The marketing center located in Shanghai North Bund covers 1200 square meters and the production bas