7 Phase Voltage Protection Relay Test System / Overcurrent Test K3066Li - K3066Li
7 Phase Voltage Protection Relay Test System / Overcurrent Test K3066Li For Sale, Most Competitive Price, Fast Delivery, Custom Service, Wholesale 7 Phase Voltage Protection Relay Test System / Overcurrent Test K3066Li, Made in China, High Quality Products!, China cheap prodocuts, china suppliers Supplier, Manufacturer.?
7 Phase Voltage Protection Relay Test System / Overcurrent Test K3066Li
?
Unique power switch and amplifier technology
4 pairs Binary output
Power:2000VA
6-phase AC (L-N)
?
?
?Friendly PC software for easy operation!
K30 series relay tester is extremely design for overseas user, with Friendly PC software as your need, unique features and functions helps you all the way!
?
1. Unique self-protection system assure the powerful protection when instrument is operating, automatic stop the output when the network is abnormal ;
2. Unique power switch and amplifier technology, so the output precision and power efficiency and factor are increased, which conforms to international tendency of energy save and environmental protection;
3. With alarm function of housing grounding testing and external voltage input, to guaranty personal security;
4. Two in one of meter and source, with function of both internal and external testing, self-calibration, oscillograph, and the duration of each oscillograph reaches 50S (optional function);
5. Offer independent Aux. DC to tested devices, 0 ~ 300V/0.6A (Poleless and adjustable);
6. Function of transducer and energy meter testing (optional function);
7. Testing interface offer unique output monitoring function and Pre-curve-tracing function, helps more on the spot analysis;
?
?Technical Data of K3066Li
?
- - - -
Voltage?generators |
Setting? Range | 7-phase?AC?(L-N) | 7?x?0?...?300?V? |
2-phase?AC?(L-L) | 2?x?0?...?600?V |
Power | 7-phase?AC?(L-N) | 7?x?110VA, ?at?0?...?300?V |
2-phase?AC?(L-L) | 2?x?220VA, ?at?0?...?600?V |
Accuracy | <0.07%?reading?+?0.03%?range?guaranteed? at?0?...?300?V <0.02%?reading?+?0.01%?range?typical? at?0-300V |
Resolution | 1mV |
Current?generators |
Setting? Range | 6-phase?AC?(L-N) | 6?x?0?...?30?A |
3-phase?AC?(2L-N) | 3?x?0?...?60?A?(Group?A?II?B) |
1-phase?AC?(3L-N) | 1?x?0?...?180?A? |
Power | 6-phase?AC?(L-N) | 6x?450VA?, at?0?...?30A? |
3-phase?AC?(2L-N) | 3x?600VA, ?at?0?...?60A?(Group?A?II?B)? |
1-phase?AC?(3L-N) | 1?x?1500?VA, ?at?0?...?180A?(Max.) |
Accuracy | <0.07%?reading?+?0.06%?range?guaranteed?at?0-30A? <0.02%?reading?+?0.02%?range?typical?at?0-30A |
Resolution | 1mA |
Generators, ?general |
Frequency | Range | 0?...?1000?Hz |
Accuracy?/?drift | Error?0.001Hz?at?10?...?65Hz, Error?0.01Hz??at?65Hz...450Hz Error?0.02Hz??at?450Hz...1000Hz |
Resolution | 0.001Hz |
Phase | Range | -?360°?...?+360° |
Accuracy?/?drift | Error?0.2?° |
Resolution | 0.1° |
Timer | Range | Infinite |
Accuracy?/?drift | Error<0.1ms |
DC?generators |
Voltage?ranges | 0?...?300V/110W |
Current?ranges | 0?...?20A/300W |
Accuracy | <0.07%?reading?+?0.03%?range?guaranteed?at?0-300V? <0.04%?reading?+?0.02%?range?typical?at?0-300V |
<0.14%?reading?+?0.06%?range?guaranteed?at?0-20A <0.05%?reading?+?0.02%?range?typical?at?0-20A |
Resolution | 1mA;?1?mV |
Aux?DC?Supply |
Range | 0...300V/110W |
Binary?inputs |
Number | 8?pairs |
Compatible?Voltage | 10V?...?250V??DC |
Binary?outputs |
Number | 4?Pairs |
Capacity | 250V/3A??AC/DC |
Synchronization |
Synchronization?mode | GPS |
Harmonic |
Harmonic?overlap?times | 2?...?20?times |
Power?supply |
Nominal?input?voltage | 85V…264V?ac |
Power | 2000VA |
Nominal?frequency | 47Hz….65Hz |
Environmental?conditions |
Operation?temperature | -5°C?...?55?°C |
Storage?temperature | -20°C?...?75?°C |
Humidity?range | 5%?...?90?%, ?non-condensing |
Weight | 17.5?KG |
Dimensions | 480(D)×140?(W)×360?(H)?mm |
PC?connection | RJ45 |
- - - -
?
K30?Series?Protection?Relay?Test?Set:
?
- - - -
Model | Channels | AC?Outputs |
K3063i?/?K3063Li | 10?output?channels | 6*30A/3*40A/4*300V |
K3030i?/?K3030Li | 7?output?channels | 3*30A/4*300V |
K3066 | 13?output?channels | 6*20A/3*40A/7*130V |
K3063 | 10?output?channels | 6*20A/3*40A/4*130V |
K3040 | 7?output?channels | 3*40A/4*130V |
K3030 | 7?output?channels | 3*30A/4*130V |
- - - -
?
Major Functions:
?
- - - -
Items | IEEE(R)?No. |
Synchronization?relay | ? |
Fault?transplay | ? |
GPS?Synchronization? | ? |
Overcurrent?relays | 50/76 |
Inverse?time?overcurrent?relays | 51 |
Undercurrent?relays | 37 |
Ground?fault?relays | 50 |
Directional?overcurrent?relays | 67 |
Directional?ground?fault?relays | 67N |
Overvoltage?relays | 59 |
Undervoltage?relays | 27 |
Directional?voltage?relays | 91 |
Directional?power?relays | 32 |
Power?factor?relays | 55 |
Differential?protection?(differential?circuits) | 87 |
Distance?protection?equipment?(phase?by?phase) | 21 |
Negative?sequence?overcurrent?relays | 46N |
Motor?overload?protection | 51/86 |
Automatic?reclosing?devices? | 79 |
Tripping?relays | 94 |
Voltage?regulating?relays | ? |
Overimpedance?relays, ?Z> | ? |
Underimpedance?relays, ?Z | ? |
Time-delay?relays | ? |
- - - -
?
?
Electric Automation Company
Address: 6F, Block 4CD, TianAn Cyber Park, Shenzhen, Guangdong, China, 518000
Tel: 86-755-83418941
Kingsine Electric Automation Co., Ltd. has been specializing in R&D, production and sales of Electric Testing & Measurement Instruments since 1999 foundation who is also honored as the High-tech enterprise certification and Software enterprise certificate recognized by China authority. With