1000W 24v To 220v Inverter Off Grid Pure Sine Wave With FCC Certification For Sale, Most Competitive Price, Fast Delivery, Custom Service, Wholesale 1000W 24v To 220v Inverter Off Grid Pure Sine Wave With FCC Certification, Made in China, High Quality Products!, China cheap prodocuts, china suppliers Supplier, Manufacturer.1000W DC TO AC 24v to 220v off grid pure sine wave power solar inverter with FCC certification
Model :?LI-10224
?
DSP smart chip Core: An individual 64-bit DSP control chip, more text samples and control functions
The detection and control program is written into the DSP chip. The results are fetched by DSP chip and the inverter is controlled by DSP chip. The advantage is that the value is accurate(by effective value). Tolerance is less than 0.01%
?
B. Most of inverters in the market are controlled by hardware circuit.
Disadvantages:
1.Components will have the ageing problems.
2.Complicated production processes, full of wires, which will raise not only the manual defects during production and after sales problem.
?
?
Photoelectricity isolation circuitry technology:
Top One: It can detect and modulate the pulse width of boost circuit, reduce the EFT(Electric Fast Transient) and raise anti-interference.
Other: The inverter without this function. Which will cause high EFT(Electric Fast Transient) and low anti-interference.
?
- - - -
Model | LI-351 | LI-501 | LI-601 | LI-102 | LI-152 | LI-202 | LI-302 | LI-502 | LI-702 | LI-103 | LI-153 | LI-203 |
Rated Power | 350W | 500W | 600W | 1KW | 1.5KW | 2KW | 3KW | 5KW | 7KW | 10KW | 15KW | 20KW |
Peak Power | 700W | 1000W | 1200W | 2KW | 3KW | 4KW | 6KW | 10KW | 14KW | 20KW | 30KW | 40KW |
Nominal battery voltage | 12VDC | 12VDC/24VDC | 24VDC/48VDC | 48VDC | 96VDC | 192VDC |
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) / 84-120VDC (96V) / 168-240VDC (192V) |
AC Mains input range | (220/230/240VAC) 140-275VAC | 170-250VAC |
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz (50Hz/60Hz automatic recognition) |
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) / ≤84VDC (96V) / ≤168VDC (192V) alarm |
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) / ≤80VDC (96V) / ≤160VDC (192V) automatic shutdown |
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) / ≥120VDC (96V) / ≥240VDC (192V) alarm |
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) / ≥136VDC (96V) / ≥272VDC (192V) automatic shutdown |
Over load protection | 110% more than rated capacity, automatic shutdown |
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown |
Short circuit protection | Automatic shutdown |
Output | Transfer efficiency | ≥85% |
Output voltage | (DC battery mode) 220/230/240VAC±2% |
Output frequency | (DC battery mode) 60/50Hz±1% |
Output wave form | Pure sine wave |
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) |
AVR output stablizer | AC mains<140VAC±5% swtich to DC battery mode, AC mains>150VAC ±5% return to AC mains mode; |
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; |
The above is for output 220V system reference, 230V/240V output just multiply by percentage |
Output frequency | (AC mains mode) automatic tracing from AC input |
Other | Transfer time | ≤10ms |
Display | LCD Display with function buttons |
Cooling system | Intelligent cooling fan control system |
≤42℃ slow fan, ≥45℃ fast fan |
AC Charger | AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V)/108.8-113.6VDC(96V)/217.6-227.2VDC(192V) |
AC charging current | Steady 15A |
AC over charge protection | Battery ≧16V (12V) ≧32V (24V) ≧64V (48V) ≧128V (96V) ≧256V (192V), stop charging after 60s alarm |
Working mode
(Optional) | 01 | AC mains priority |
Always use AC mains as priority input to provide AC output and automatically charge the battery, |
only stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off |
02 | Energy saving |
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on |
03 | DC battery priority |
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts DC to |
AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC output and |
automatically start charging the battery (for 24V/48V/96V/192V system, multiply by 2/4/8/16 accordingly) |
Comnunication | RS-232/USB/SNMP(additional option) |
Environment | Temperature | -20~75℃ |
Humidity | <95% |
Appearance | Product size (mm) | 300*240*120 | 410*225*410 | 485*300*655 |
Packing size (mm) | | | |
Net Weight (kg) | 7.2 | 7.5 | 7.5 | 8.7 | 23.5 | 25.5 | 28.8 | 55 | 56 | 85 | 105 | 125 |
Gross Weight (kg) | | | | | | | | | | | | |
*Product specifications are subject to change without further notice |
- - - -
Foshan Top One Power Technology Co., Ltd
Address: 5F, Bldg.2,,No.117 Zhangchayi Road, Guangzhou, Guangdong, China, 510000
Tel: +86-757-82589781
Foshan Top One Power Technology Co., Ltd 聽is specializing in manufacturing and marketing high quality new energy proudcts, the main products include inverter, power Inverter,solar power inverter, solar controller, pure sine wave inverter, frequency inverter,battery inverter, solar controller, a