Locks

Share us

Heavy Duty AC 110V / 220V Automatic Vehicle Barrier Gate For Parking Lot

DZTP-139-A

Description

Heavy Duty AC 110V / 220V Automatic Vehicle Barrier Gate For Parking Lot

?

Work with WONSUN

?

1.One year& acute;s free servicing is supplied( not including the arm)
2. Lifetiom charged servicing is offered.
3. Technology servicing is supplied
The following situations are charged for servicing (or changing):
1. Broken by wrong installation.
2 Broken by improper voltae.
3. The surfaces of the system destroyed by wrong installation our use.
4. Broken by natural disaster.
5. Overdue
6. Servicing items out of our promises.
The upgrade and improvement of the product won& acute;t be notified if there is any.
The explaining ?authority of this product instruction and service article belong to the production factory.

?


Model Selection and Differences

?



?


Specifications

?

- - - -
Model | WST1211 |
Working Temperature | -40℃~+75℃ |
Voltage | 220V±10%, 110V±10%, 50/60HZ |
Rated power | 80W |
Relative humidity | ≤90% |
Remote control distance | ≥30m |
Net weight | 48kgs |
Speed | 1S,1.8S,3S, 6S |
Max boom length | 6 meters |
Motor Rotational speed | 1400rmp |
Protection Degree | IP44 |
- - - -


?
Communication with customers
?
1)?????Q:?Connected power and press open/close button but traffic barrier gate no action?

?

- - - -
A | Reason | Solution |
1 | Fuse blown | Check fuse and power in controller |
2 | Battery?of remote control powered off | Change a new one |
3 | External protection circuit break or at protecting status | Open the barrier door and click OPEN/CLOSE button on control box |
4 | Same frequency interference | Check photocell and loop detector |
- - - -

?
2) Q:Connected power and press open/close button,traffic barrier gate will move but even when it is at right position, the motor still running and not stop?
?

- - - -
A | Reason | Solution |
1 | Limit switch | Adjust the horizontal/vertical limit switch to correct position |
2 | Main controller failure | Change a new one |
- - - -

?
3)???Q:?Motor running but traffic barrier gate arm no action?
?

- - - -
A | Reason | Solution |
1 | Barrier arm at 45° position where is hard to move | Unlock clutch and manually rotate arm to horizontal or vertical position then try again |
2 | Tension of balancing spring not suitable | Adjust spring exactly |
3 | Low working voltage | Check the voltage and power |
- - - -

?
4)??Q:?When opening/closing,traffic barrier gate arm cannot reach right position (90° vertical & 180° horizontal)?
?

- - - -
A. | Reason | Solution |
1 | Length adjustment of connecting rod not correct | Open barrier door and unlock clutch to check when arm at 90°?vertical position if the master rod covers slave one; when arm at 180°?horizontal position if master rod and slave one are in the same straight line |
2 | Nuts on the limit switch loose | Tighten the nuts when arm at 90°?vertical and 180°?horizontal? ? ? |
- - - -

?

?

1 pcs Gate Barrier
1 pcs arm boom (from 1m to 6m can customised)
1 pcs control panel(built inside)
2 pcs remote controllers
1 pcs manual book

?

cheap prodocuts, china suppliers,

Read More

Previous

High Sensitive 1400rmp Automatic Parking Gate Barrier With 6 Meters Boom...

Previous

CE Approved Heavy Duty Automatic Barrier Gate for Car Parking Lot System...

Shenzhen Wonsun Machinery & Electrical Technology Co. Ltd

Automatic Barrier Gate,Parking Barrier Gate,Vehicle Barrier Gate

Address: Longgang Shenzhen City, China,
Shenzhen, Guangdong
China, 518000